1 edition of Tissue impedance and current flow in the implanted ear found in the catalog.

Tissue impedance and current flow in the implanted ear

Tissue impedance and current flow in the implanted ear

implications for the cochlear prosthesis

  • 193 Want to read
  • 15 Currently reading

Published by Annals Pub. Co. in St. Louis, Mo .
Written in English

    Subjects:
  • Cochlea,
  • Ear -- Surgery

  • Edition Notes

    Includes bibliographies

    Other titlesNeural mechanisms relevant to the design of an auditory prosthesis
    StatementFrancis A. Spelman, Ben M. Clopton, Bryan E. Pfingst. Neural mechanisms relevant to the design of an auditory prosthesis : location and electrical characteristics / Ben M. Clopton, Francis A. Spelman.
    SeriesAnnals of otology, rhinology & laryngology -- 98
    ContributionsSpelman, Francis A, Clopton, Ben M. 1942-, Pfingst, Bryan E
    The Physical Object
    Pagination14 p. :
    Number of Pages14
    ID Numbers
    Open LibraryOL22810648M

    Impedance, expressed in Ohms, is the ratio of the voltage impressed across a pair of terminals to the current flow between those terminals. In direct-current (DC) circuits, impedance corresponds to resistance. In alternating current (AC) circuits, impedance . A macroshock situation is when current is applied to tissue far from the organ of interest, usually the heart. The current is then spread out more or less uniformly, and rather large currents are needed in .

    Scott Giles NPTE book review, v page - Learn with flashcards, games, and more — for free. Search. increased current flow. direct current. over the anterior cervical area and over electronic implants. Russian current. Seaver L Soon MD, Carl V Washington Jr MD, in Surgery of the Skin, Electrocoagulation. Electrocoagulation uses low-voltage, moderately damped or partially rectified, high-amperage current in a biterminal fashion to cause deeper tissue destruction and hemostasis with minimal carbonization (Fig. ).Low voltage is sufficient to establish current flow .

    As with any material implanted in the body, it is important to minimize or eliminate foreign body response and maximize effectual integration. Neural implants have the potential to increase the quality of life for patients with such disabilities as Alzheimer's, Parkinson's, epilepsy, depression, and the complexity of interfaces between a neural implant and brain tissue. Cochlear implant (CI) performance varies dramatically between subjects. Although the causes of this variability remain unclear, the electrode-neuron interface is thought to play an important role. Here we .


Share this book
You might also like
The Beat Fatigue Workbook

The Beat Fatigue Workbook

60-Minute Investment Planner

60-Minute Investment Planner

Problems in science education (particularly in the 9-13 age range) and the possible role of television in their solution.

Problems in science education (particularly in the 9-13 age range) and the possible role of television in their solution.

Maximum price regulations and resulting parallel and black markets

Maximum price regulations and resulting parallel and black markets

They went that-a-way

They went that-a-way

Authorizations for the Public telecommunications financing act of 1978

Authorizations for the Public telecommunications financing act of 1978

Development of hypersonic engine seals

Development of hypersonic engine seals

Bargain bride.

Bargain bride.

Muskoka Regional Health Centre

Muskoka Regional Health Centre

Torture

Torture

A discovery of new light, or, Ancient truthes revived

A discovery of new light, or, Ancient truthes revived

Bats in the belfry

Bats in the belfry

Economic evaluation of watershed management projects

Economic evaluation of watershed management projects

Janes pocket book of submarine development

Janes pocket book of submarine development

Murder Is Pathological

Murder Is Pathological

Vigilante days and ways

Vigilante days and ways

athenian drama

athenian drama

Tissue impedance and current flow in the implanted ear Download PDF EPUB FB2

Tissue impedance and current flow in the implanted ear. Implications for the cochlear prosthesis. Spelman FA, Clopton BM, Pfingst BE. Tissue impedance was measured in the cochleas of monkeys and guinea pigs implanted Cited by: Get this from a library.

Tissue impedance and current flow in the implanted ear: implications for the cochlear prosthesis. [Francis A Spelman; Ben M Clopton; Bryan E Pfingst]. Investigators have studied the passive electrical properties of the inner ear to provide information about B.M., and Pfingst, B.E.

Tissue impedance and current flow in the implanted ear: Implications for the cochlear prosthesis. Ann. Otol. Spelman F.A. () Determination of Tissue Impedances of the Inner Ear Cited by: 7. Tissue impedance and current flow in the implanted ear. Implications for the cochlear prosthesis.

Annals of Otology, Rhinology & Laryngology, 98, 3–: Kelly N. Jahn, Kelly N. Jahn, Molly D. Bergan, Julie G. Arenberg, Julie G. Arenberg. In humans, a low current level is often applied to prevent tissue damage. 8 Compared to the high resistivity of thoracic tissue (ρ = –5, Ω cm), blood and fluid (ρ = 65– Ωcm) provide much lower resistance to current.

9 Thus, regions of the body with higher blood or fluid content will present with lower impedance, whereas regions with more solid tissue Cited by: The objective of the study was to explore the effect of electrode encapsulation by fibrous scar tissue on electrical potential distributions and auditory nerve fibre excitation patterns.

Voltage and current in the electrode wires are measured and they define the immittance. However, in the tissue volume the current flow must be defined with both magnitude and direction, and the parameter is the current density, a spatial vector.

The current. Little work has been reported which characterises the electrical behaviour of electrode materials used for extracochlear stimulation.

Electrode properties were investigated to optimise preparation methods and. Hearing Research. 12 () Eisevier HRR Multichannel electrical stimulation of the auditory nerve in man. Channel interaction Robert n Coleman Laboratory, University of California.

In principle, electrical stimulation of the cochlea is a simple process. Intracochlear electrodes, when stimulated, create electrical field patterns within the cochlea.

In the vicinity of the neural elements. A series of animal experiments was conducted to characterize changes in the complex impedance of chronically implanted electrodes in neural tissue.

Consistent trends in impedance changes were observed across all animals, characterized as a general increase in the measured impedance. We, therefore, hypothesized that the most significant contribution to the measured Z is from the electrode-tissue interface where there is high impedance to electrical flow, and that beyond this interface the contribution to the measured Z is negligible.

This is because beyond the electrode-tissue interface the current finds its way to flow. Implantable neuroprostheses such as cochlear implants, deep brain stimulators, spinal cord stimulators, and retinal implants use charge-balanced alternating current (AC) pulses to recover delivered charge and thus mitigate toxicity from electrochemical reactions occurring at the metal-tissue.

The shape and the electrode material have large impact of the current flow distribution around the electrodes, as well as the contact impedance between the electrodes and the brain tissue.

This work determines the contact impedance. The major function of the middle ear is to match relatively low-impedance airborne sounds to the higher-impedance fluid of the inner ear.

The term “impedance” in this context describes a medium's resistance to movement. Normally, when sound travels from a low-impedance medium like air to a much higher-impedance. Abstract: Those suffering from a severe to profound sensorineural hearing loss can obtain substantial benefit from a cochlear implant prosthesis.

An electrode array implanted in the inner ear stimulates auditory nerve fibers by direct injection of electrical current. A major limitation of today's technology is the imprecise control of intracochlear current flow. Clinical impedance measurements for deep brain stimulation (DBS) electrodes in human patients are normally in the range – Ω.

DBS devices utilize voltage-controlled stimulation; therefore, the current delivered to the tissue is inversely proportional to the impedance. The measurement of tissue impedance was first a pplied to impedance plethysmography. The most successful application of this technique, however, is impedance cardiography, which can be used for the.

A common objective measure used to assess device and electrode function is impedance (a measure of the resistance to current flow). Impedance measures are affected by the electrode-tissue interface, resistivity in the fluid/tissue medium, and resistivity of the electrode contact and lead wires.

It is not uncommon to encounter impedance abnormalities. Impedances within the normal range (when measured in the common ground mode of stimulation) suggest that current flow occurs in the tissue and fluid of the cochlea.

Low impedance measurements may suggest that particular electrodes are short circuiting, whereas high impedances.

A. Tissue Impedance Circuit Explanation As discussed earlier, a simplified model of tissue impedance consists of a parallel Rt and Cc. Nominal values for Rt and Cc are Rt = 2 kΩ and Cc = nF.

To .Unit 2: Impedance & The Ear. STUDY. Flashcards. Learn. Write. Spell. Test. PLAY. Match. Gravity. Created by. hoevem. Terms in this set (70) Impedance. the net opposition to the flow of energy created by resistance (R) and reactance (X) measured in Ohms (Ω) tough, fibrous, connective tissue .There is a limit to the amount by which the electrode size can be decreased.

The reason is that one has to reach the required threshold current with a fixed battery voltage, and this limits the maximum allowable circuit impedance. The latter, however, is mainly the electrode-tissue impedance.